Loading...
2 results
Search Results
Now showing 1 - 2 of 2
- Keratoconus and Visual Performance with Different Contact LensesPublication . Marta, Ana; Marques, Joao Heitor; Almeida, Daniel; José, Diana; Barbosa, IrenePurpose: To analyze the visual performance in contact lens wearers with keratoconus. Methods: A retrospective study including contact lens (CL) wearers was performed. The current best-corrected visual acuity with contact lens (BCVA-CL) and with spectacles (BCVA-S) correction, contrast sensitivity (CS) (by Metrovision-MonPack3®), analysis of light scattering in the retina and vision break-up time (HD Analyzer®), and corneal tomography (Oculus Pentacam® HR) were evaluated. Results: This study included 96 eyes of 59 patients with Keratoconus. Rigid gas permeable contact lenses (RGPCL), hybrid contact lenses (HCL), and silicone hydrogel/hydrogel contact lenses (HGCL) were fitted in 67, 17, and 12 eyes, respectively. Dynamic objective scatter index (OSI) (p = 0.024), minimum OSI (p = 0.037) and maximum OSI (p = 0.040) were significantly better with RGPCL and worse with HGCL. Mean CS in photopic conditions was significantly worse with HGCL and better with HCL (p = 0.006), without differences in mesopic conditions (p = 0.121). RGPCL wearers showed a higher mean K (p = 0.020), and a lower corneal thickness at the thinnest point (p=0.011). Conclusion: Visual quality varied significantly with different types of CL. Although RGPCL was fitted in patients with worse Pentacam tomographic parameters, RGPCL was associated with a better dynamic visual quality.
- Asymmetric Thickness Intracorneal Ring Segments for KeratoconusPublication . Baptista, Pedro Manuel; Marques, Joao Heitor; Neves, Miguel Mesquita; Gomes, Miguel; OLIVEIRA, LUISPurpose: To describe the anatomical and functional results of the implantation of asymmetric thickness intracorneal ring segments (AS-ICRS) in eyes with keratoconus and asymmetric/irregular astigmatism (type 2 - Duck - and type 3 - Snowman - phenotypes, Fernandez-Vega/Alfonso morphologic Keratoconus classification). Materials and methods: Retrospective observational study including 19 consecutive patients (21 eyes) with keratoconus who underwent manual implantation of the Keraring® Asymmetric ICRS (AS). Analysis included demographic and clinical data and Pentacam (Oculus®) measurements: topographic astigmatism; topographic flat meridian (K1), steepest meridian (K2) and the maximum keratometric point (Kmax); total root mean square (RMS) and high order RMS (HOA) aberrations and comatic Zernike coefficients (Z31;Z3-1) at 0º and 90º meridians. Results: Overall mean age was 35.3±11.7 years and median follow-up was 7.1 months (range 6-12). At the end of follow-up, a significant improvement from baseline was achieved in both UDVA (0.24±0.22; p=0.017) and CDVA (0.21±0.17; p<0.001). Regarding topographic measurements, the greatest decrease was observed in K2 (2.76±1.9D; p<0.001) and astigmatism (1.97±1.5; p<0.001). Aberrometry analysis showed a reduction of 1.27±3.2µm in the total RMS (p=0.085), 0.24±0.9µm in HOA (p=0.227) and 0.78±0.5 (p<0.001) in the 90º component of comatic aberration. The procedure effects in the CDVA, topographic and aberrometric parameters were higher in type 2 cones without statistical significance (p>0.05 in all). Conclusion: Implantation of the Keraring® Asymmetric ICRS in keratoconus with asymmetric/irregular astigmatism allowed an improvement of several clinical, topographic and aberrometric parameters, with clinical efficacy and safety, with a tendency to a greater effect in the type 2 cones.