Immediate Reactions to Fluorescein and Indocyanine Green in Retinal Angiography: Review of Literature and Proposal for Patient’s Evaluation

dc.contributor.authorMeira, Jorge
dc.contributor.authorMarques, Maria Luís
dc.contributor.authorFalcão-Reis, Fernando
dc.contributor.authorGomes, Eva
dc.contributor.authorCarneiro, Ângela
dc.date.accessioned2021-11-16T15:01:17Z
dc.date.available2021-11-16T15:01:17Z
dc.date.issued2020-01-20
dc.description.abstractIntroduction: Contrast rapid sequence angiography with fluorescein or indocyanine green (ICG) is a diagnostic procedure commonly used in ophthalmology. Adverse reactions to fluorescein and ICG are rare and may be classified as toxic, of hypersensitivity and non-specific. The evaluation and management of a patient with an adverse reaction is a challenge for the majority of ophthalmologists, as is the assessment of risk factors that may contraindicate the procedure. Purpose: We aim to review the concepts underlying adverse reactions to fluorescein and ICG, especially those of hypersensitivity, and present a proposal or the evaluation of the patients in need to perform retinal angiography and for the treatment of immediate reactions to fluorescein and ICG. Methods: The available literature was examined using PubMed-Medline, and using the MeSH terms "fluorescein", "Indocyanine green", "ophthalmic dyes", "retinal angiography", "adverse reactions", and "allergic reaction". Conclusion: This review may help ophthalmologists to identify patients with higher risk of a hypersensitivity reaction and give them tools to recognize patients with suspected hypersensitivity that may benefit from an allergy study.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationMeira J, Marques ML, Falcão-Reis F, Rebelo Gomes E, Carneiro Â. Immediate Reactions to Fluorescein and Indocyanine Green in Retinal Angiography: Review of Literature and Proposal for Patient's Evaluation. Clin Ophthalmol. 2020;14:171-178. doi:10.2147/OPTH.S234858pt_PT
dc.identifier.doi10.2147/OPTH.S234858pt_PT
dc.identifier.issn1177-5483
dc.identifier.issn1177-5467
dc.identifier.urihttp://hdl.handle.net/10400.16/2564
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherDove Medical Presspt_PT
dc.relation.publisherversionhttps://www.dovepress.com/immediate-reactions-to-fluorescein-and-indocyanine-green-in-retinal-an-peer-reviewed-fulltext-article-OPTHpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/pt_PT
dc.subjectadverse reactionspt_PT
dc.subjectfluoresceinpt_PT
dc.subjecthypersensitivity reactionpt_PT
dc.subjectindocyanine greenpt_PT
dc.subjectophthalmic dyespt_PT
dc.subjectretinal angiographypt_PT
dc.titleImmediate Reactions to Fluorescein and Indocyanine Green in Retinal Angiography: Review of Literature and Proposal for Patient’s Evaluationpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceNew Zealandpt_PT
oaire.citation.endPage178pt_PT
oaire.citation.startPage171pt_PT
oaire.citation.titleClinical Ophthalmologypt_PT
oaire.citation.volume14pt_PT
person.familyNameMarques
person.familyNamegomes
person.givenNameMaria Luís
person.givenNameeva
person.identifier.ciencia-id0D1C-83A7-A086
person.identifier.orcid0000-0003-2241-7889
person.identifier.orcid0000-0001-8956-9145
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication2c13fded-1c84-4901-8a8f-249d0e371a69
relation.isAuthorOfPublication7e99b85c-5096-43a3-800b-02207a45237d
relation.isAuthorOfPublication.latestForDiscovery2c13fded-1c84-4901-8a8f-249d0e371a69

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Meira-2020-Immediate-reactions-to-fluorescein-.pdf
Size:
264.36 KB
Format:
Adobe Portable Document Format