Visian® ICLV4c™ and Artiflex®: Comparative Analysis with the HD Analyser™ and Integration with Subjective Performance and Anatomical Parameters

dc.contributor.authorBaptista, Pedro Manuel
dc.contributor.authorMonteiro, Sílvia
dc.contributor.authorAbreu, Ana Carolina
dc.contributor.authorPoças, João
dc.contributor.authorJosé, Diana
dc.contributor.authorLume, Miguel
dc.contributor.authorPinto, Maria do Céu
dc.date.accessioned2021-11-16T14:41:09Z
dc.date.available2021-11-16T14:41:09Z
dc.date.issued2020-12-30
dc.description.abstractPurpose: To analyze and compare the mid-term objective and subjective performance of two phakic intraocular lenses (PIOLs) - Visian® ICL™ V4c and Artiflex® and to correlate those results with anatomical parameters. Patients and methods: Observational retrospective study including thirty patients (15 for each PIOL) randomly selected from those who underwent bilateral implantation of one of the PIOLs (60 eyes were analysed). Uncorrected and corrected distance visual acuities (UDVA and CDVA), anterior chamber structural parameters, and corneal endothelial cells density and morphology were evaluated. Quality of vision was assessed both subjectively with a questionnaire, and objectively using a double-pass technology optical quality analysis system. Results: At the end of follow-up the Artiflex® group showed better UDVA (0.95±0.11 vs 0.99±0.05, p=0.027) and higher proportion of eyes reaching at least 20/20 (28/30 vs 18/30, p=0.005). Excellent and similar objective scatter index (1.79±0.9 vs 2.14±1.6, p=0.306) and modular transfer function cutoff frequency (26.91±9.2 vs 26.51±11.9, p=0.784) results were achieved in the HD Analyzer® and the questionnaire showed comparable high Satisfaction (55.7±3.5 vs 54.3±5.4, p=0.386) and low Dysphotopsia Scores (3.1±1.8 vs 2.1±2.2, p=0.213). The ICL group showed inferior anterior chamber volume (p<0.001), and angle (p<0.001) and superior pupillary diameter (p=0.007). Minimum follow-up was 24 months. Conclusion: Both the Visian® ICLV4c™ and the Artiflex® showed excellent optical performance through the HD AnalyzerTM technology, translated in high patient satisfaction. Overall, both PIOLs showed similar safety, predictability, stability and effectiveness of for the reduction of high sphero-cylindrical refractive errors, despite better UDVA results with the Artiflex®.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationBaptista PM, Monteiro S, Abreu AC, et al. Visian® ICLV4c™ and Artiflex®: Comparative Analysis with the HD AnalyserTM and Integration with Subjective Performance and Anatomical Parameters. Clin Ophthalmol. 2020;14:4541-4549. doi:10.2147/OPTH.S290611pt_PT
dc.identifier.doi10.2147/OPTH.S290611pt_PT
dc.identifier.issn1177-5467
dc.identifier.issn1177-5483
dc.identifier.urihttp://hdl.handle.net/10400.16/2560
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherDove Medical Presspt_PT
dc.relation.publisherversionhttps://www.dovepress.com/visianreg-iclv4ctrade-and-artiflexreg-comparative-analysis-with-the-hd-peer-reviewed-fulltext-article-OPTHpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/pt_PT
dc.subjectArtiflex®pt_PT
dc.subjectHD AnalyzerTMpt_PT
dc.subjectVisian® ICLV4c™pt_PT
dc.subjectastigmatismpt_PT
dc.subjectdysphotopsiapt_PT
dc.subjectglarept_PT
dc.subjecthalospt_PT
dc.subjecthigh myopiapt_PT
dc.subjectphakic intraocular lenspt_PT
dc.subjectsphericpt_PT
dc.subjecttoricpt_PT
dc.titleVisian® ICLV4c™ and Artiflex®: Comparative Analysis with the HD Analyser™ and Integration with Subjective Performance and Anatomical Parameterspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceNew Zealandpt_PT
oaire.citation.endPage4549pt_PT
oaire.citation.startPage4541pt_PT
oaire.citation.titleClinical Ophthalmologypt_PT
oaire.citation.volume14pt_PT
person.familyNameBaptista
person.familyNameMonteiro
person.familyNameAbreu
person.familyNameJosé
person.familyNameLume
person.givenNamePedro Manuel
person.givenNameSílvia
person.givenNameAna Carolina
person.givenNameDiana
person.givenNameMiguel
person.identifier.orcid0000-0001-8285-1084
person.identifier.orcid0000-0001-5040-6170
person.identifier.orcid0000-0003-4842-8623
person.identifier.orcid0000-0002-8415-0780
person.identifier.orcid0000-0002-8629-1288
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationaefa59ff-77f9-42ff-ac9b-88373f5c2ac8
relation.isAuthorOfPublication581655ee-2021-42a9-aca2-e1f207cce842
relation.isAuthorOfPublicationeab24879-bc6b-47e8-8c97-fb00e822e7e9
relation.isAuthorOfPublication82af911d-7ad4-45a9-9d96-bdbf43ed20ce
relation.isAuthorOfPublication02b8e986-9270-441a-81f0-4042aef41dba
relation.isAuthorOfPublication.latestForDiscoveryaefa59ff-77f9-42ff-ac9b-88373f5c2ac8

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Baptista-2020-Visian-iclvctm-and-artiflex-compara.pdf
Size:
1.22 MB
Format:
Adobe Portable Document Format