Repository logo
 
Publication

Keratoconus and Visual Performance with Different Contact Lenses

dc.contributor.authorMarta, Ana
dc.contributor.authorMarques, Joao Heitor
dc.contributor.authorAlmeida, Daniel
dc.contributor.authorJosé, Diana
dc.contributor.authorBarbosa, Irene
dc.date.accessioned2023-10-23T08:22:25Z
dc.date.available2023-10-23T08:22:25Z
dc.date.issued2021-12
dc.description.abstractPurpose: To analyze the visual performance in contact lens wearers with keratoconus. Methods: A retrospective study including contact lens (CL) wearers was performed. The current best-corrected visual acuity with contact lens (BCVA-CL) and with spectacles (BCVA-S) correction, contrast sensitivity (CS) (by Metrovision-MonPack3®), analysis of light scattering in the retina and vision break-up time (HD Analyzer®), and corneal tomography (Oculus Pentacam® HR) were evaluated. Results: This study included 96 eyes of 59 patients with Keratoconus. Rigid gas permeable contact lenses (RGPCL), hybrid contact lenses (HCL), and silicone hydrogel/hydrogel contact lenses (HGCL) were fitted in 67, 17, and 12 eyes, respectively. Dynamic objective scatter index (OSI) (p = 0.024), minimum OSI (p = 0.037) and maximum OSI (p = 0.040) were significantly better with RGPCL and worse with HGCL. Mean CS in photopic conditions was significantly worse with HGCL and better with HCL (p = 0.006), without differences in mesopic conditions (p = 0.121). RGPCL wearers showed a higher mean K (p = 0.020), and a lower corneal thickness at the thinnest point (p=0.011). Conclusion: Visual quality varied significantly with different types of CL. Although RGPCL was fitted in patients with worse Pentacam tomographic parameters, RGPCL was associated with a better dynamic visual quality.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationMarta A, Marques JH, Almeida D, José D, Barbosa I. Keratoconus and Visual Performance with Different Contact Lenses. Clin Ophthalmol. 2021;15:4697-4705. doi:10.2147/OPTH.S345154pt_PT
dc.identifier.doi10.2147/OPTH.S345154pt_PT
dc.identifier.issn1177-5467
dc.identifier.issn1177-5483
dc.identifier.urihttp://hdl.handle.net/10400.16/2828
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherDove Medical Presspt_PT
dc.relation.publisherversionhttps://www.dovepress.com/keratoconus-and-visual-performance-with-different-contact-lenses-peer-reviewed-fulltext-article-OPTHpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/pt_PT
dc.subjectcontact lenspt_PT
dc.subjectkeratoconuspt_PT
dc.subjectoptical qualitypt_PT
dc.subjectvisual performancept_PT
dc.titleKeratoconus and Visual Performance with Different Contact Lensespt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceNew Zealandpt_PT
oaire.citation.endPage4705pt_PT
oaire.citation.startPage4697pt_PT
oaire.citation.titleClinical Ophthalmologypt_PT
oaire.citation.volume15pt_PT
person.familyNameMarta
person.familyNameMarques
person.familyNameAlmeida
person.familyNameJosé
person.familyNameBarbosa
person.givenNameAna
person.givenNameJoao Heitor
person.givenNameDaniel
person.givenNameDiana
person.givenNameIrene
person.identifier.orcid0000-0003-3495-4649
person.identifier.orcid0000-0001-6487-7950
person.identifier.orcid0000-0001-6488-0949
person.identifier.orcid0000-0002-8415-0780
person.identifier.orcid0000-0001-6053-5339
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication27861687-928c-4618-9f11-92d74ec326e0
relation.isAuthorOfPublicationb1e9a3af-258b-4e7c-9ea6-bb2f67e31bfd
relation.isAuthorOfPublicationa8e8efda-5640-4f2b-9aaa-e90cab5bacec
relation.isAuthorOfPublication82af911d-7ad4-45a9-9d96-bdbf43ed20ce
relation.isAuthorOfPublication0794e8b1-dfb3-41a9-84aa-29915b10c531
relation.isAuthorOfPublication.latestForDiscovery27861687-928c-4618-9f11-92d74ec326e0

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Marta-2021-Keratoconus-and-visual-performance-.pdf
Size:
2.42 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: