Publication
Keratoconus and Visual Performance with Different Contact Lenses
dc.contributor.author | Marta, Ana | |
dc.contributor.author | Marques, Joao Heitor | |
dc.contributor.author | Almeida, Daniel | |
dc.contributor.author | José, Diana | |
dc.contributor.author | Barbosa, Irene | |
dc.date.accessioned | 2023-10-23T08:22:25Z | |
dc.date.available | 2023-10-23T08:22:25Z | |
dc.date.issued | 2021-12 | |
dc.description.abstract | Purpose: To analyze the visual performance in contact lens wearers with keratoconus. Methods: A retrospective study including contact lens (CL) wearers was performed. The current best-corrected visual acuity with contact lens (BCVA-CL) and with spectacles (BCVA-S) correction, contrast sensitivity (CS) (by Metrovision-MonPack3®), analysis of light scattering in the retina and vision break-up time (HD Analyzer®), and corneal tomography (Oculus Pentacam® HR) were evaluated. Results: This study included 96 eyes of 59 patients with Keratoconus. Rigid gas permeable contact lenses (RGPCL), hybrid contact lenses (HCL), and silicone hydrogel/hydrogel contact lenses (HGCL) were fitted in 67, 17, and 12 eyes, respectively. Dynamic objective scatter index (OSI) (p = 0.024), minimum OSI (p = 0.037) and maximum OSI (p = 0.040) were significantly better with RGPCL and worse with HGCL. Mean CS in photopic conditions was significantly worse with HGCL and better with HCL (p = 0.006), without differences in mesopic conditions (p = 0.121). RGPCL wearers showed a higher mean K (p = 0.020), and a lower corneal thickness at the thinnest point (p=0.011). Conclusion: Visual quality varied significantly with different types of CL. Although RGPCL was fitted in patients with worse Pentacam tomographic parameters, RGPCL was associated with a better dynamic visual quality. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | Marta A, Marques JH, Almeida D, José D, Barbosa I. Keratoconus and Visual Performance with Different Contact Lenses. Clin Ophthalmol. 2021;15:4697-4705. doi:10.2147/OPTH.S345154 | pt_PT |
dc.identifier.doi | 10.2147/OPTH.S345154 | pt_PT |
dc.identifier.issn | 1177-5467 | |
dc.identifier.issn | 1177-5483 | |
dc.identifier.uri | http://hdl.handle.net/10400.16/2828 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Dove Medical Press | pt_PT |
dc.relation.publisherversion | https://www.dovepress.com/keratoconus-and-visual-performance-with-different-contact-lenses-peer-reviewed-fulltext-article-OPTH | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ | pt_PT |
dc.subject | contact lens | pt_PT |
dc.subject | keratoconus | pt_PT |
dc.subject | optical quality | pt_PT |
dc.subject | visual performance | pt_PT |
dc.title | Keratoconus and Visual Performance with Different Contact Lenses | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.conferencePlace | New Zealand | pt_PT |
oaire.citation.endPage | 4705 | pt_PT |
oaire.citation.startPage | 4697 | pt_PT |
oaire.citation.title | Clinical Ophthalmology | pt_PT |
oaire.citation.volume | 15 | pt_PT |
person.familyName | Marta | |
person.familyName | Marques | |
person.familyName | Almeida | |
person.familyName | José | |
person.familyName | Barbosa | |
person.givenName | Ana | |
person.givenName | Joao Heitor | |
person.givenName | Daniel | |
person.givenName | Diana | |
person.givenName | Irene | |
person.identifier.orcid | 0000-0003-3495-4649 | |
person.identifier.orcid | 0000-0001-6487-7950 | |
person.identifier.orcid | 0000-0001-6488-0949 | |
person.identifier.orcid | 0000-0002-8415-0780 | |
person.identifier.orcid | 0000-0001-6053-5339 | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | 27861687-928c-4618-9f11-92d74ec326e0 | |
relation.isAuthorOfPublication | b1e9a3af-258b-4e7c-9ea6-bb2f67e31bfd | |
relation.isAuthorOfPublication | a8e8efda-5640-4f2b-9aaa-e90cab5bacec | |
relation.isAuthorOfPublication | 82af911d-7ad4-45a9-9d96-bdbf43ed20ce | |
relation.isAuthorOfPublication | 0794e8b1-dfb3-41a9-84aa-29915b10c531 | |
relation.isAuthorOfPublication.latestForDiscovery | 27861687-928c-4618-9f11-92d74ec326e0 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Marta-2021-Keratoconus-and-visual-performance-.pdf
- Size:
- 2.42 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.44 KB
- Format:
- Item-specific license agreed upon to submission
- Description: