Publication
Asymmetric Thickness Intracorneal Ring Segments for Keratoconus
dc.contributor.author | Baptista, Pedro Manuel | |
dc.contributor.author | Marques, Joao Heitor | |
dc.contributor.author | Neves, Miguel Mesquita | |
dc.contributor.author | Gomes, Miguel | |
dc.contributor.author | OLIVEIRA, LUIS | |
dc.date.accessioned | 2021-11-16T14:06:50Z | |
dc.date.available | 2021-11-16T14:06:50Z | |
dc.date.issued | 2020-12-16 | |
dc.description.abstract | Purpose: To describe the anatomical and functional results of the implantation of asymmetric thickness intracorneal ring segments (AS-ICRS) in eyes with keratoconus and asymmetric/irregular astigmatism (type 2 - Duck - and type 3 - Snowman - phenotypes, Fernandez-Vega/Alfonso morphologic Keratoconus classification). Materials and methods: Retrospective observational study including 19 consecutive patients (21 eyes) with keratoconus who underwent manual implantation of the Keraring® Asymmetric ICRS (AS). Analysis included demographic and clinical data and Pentacam (Oculus®) measurements: topographic astigmatism; topographic flat meridian (K1), steepest meridian (K2) and the maximum keratometric point (Kmax); total root mean square (RMS) and high order RMS (HOA) aberrations and comatic Zernike coefficients (Z31;Z3-1) at 0º and 90º meridians. Results: Overall mean age was 35.3±11.7 years and median follow-up was 7.1 months (range 6-12). At the end of follow-up, a significant improvement from baseline was achieved in both UDVA (0.24±0.22; p=0.017) and CDVA (0.21±0.17; p<0.001). Regarding topographic measurements, the greatest decrease was observed in K2 (2.76±1.9D; p<0.001) and astigmatism (1.97±1.5; p<0.001). Aberrometry analysis showed a reduction of 1.27±3.2µm in the total RMS (p=0.085), 0.24±0.9µm in HOA (p=0.227) and 0.78±0.5 (p<0.001) in the 90º component of comatic aberration. The procedure effects in the CDVA, topographic and aberrometric parameters were higher in type 2 cones without statistical significance (p>0.05 in all). Conclusion: Implantation of the Keraring® Asymmetric ICRS in keratoconus with asymmetric/irregular astigmatism allowed an improvement of several clinical, topographic and aberrometric parameters, with clinical efficacy and safety, with a tendency to a greater effect in the type 2 cones. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | Baptista PM, Marques JH, Neves MM, Gomes M, Oliveira L. Asymmetric Thickness Intracorneal Ring Segments for Keratoconus. Clin Ophthalmol. 2020;14:4415-4421. doi:10.2147/OPTH.S283387 | pt_PT |
dc.identifier.doi | 10.2147/OPTH.S283387 | pt_PT |
dc.identifier.issn | 1177-5483 | |
dc.identifier.issn | 1177-5467 | |
dc.identifier.uri | http://hdl.handle.net/10400.16/2559 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Dove Medical Press | pt_PT |
dc.relation.publisherversion | https://www.dovepress.com/asymmetric-thickness-intracorneal-ring-segments-for-keratoconus-peer-reviewed-fulltext-article-OPTH | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ | pt_PT |
dc.subject | ICRS | pt_PT |
dc.subject | aberrometry | pt_PT |
dc.subject | astigmatism | pt_PT |
dc.subject | asymmetric | pt_PT |
dc.subject | keratoconus | pt_PT |
dc.title | Asymmetric Thickness Intracorneal Ring Segments for Keratoconus | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.conferencePlace | New Zealand | pt_PT |
oaire.citation.endPage | 4421 | pt_PT |
oaire.citation.startPage | 4415 | pt_PT |
oaire.citation.title | Clinical Ophthalmology | pt_PT |
oaire.citation.volume | 14 | pt_PT |
person.familyName | Baptista | |
person.familyName | Marques | |
person.familyName | Neves | |
person.familyName | Gomes | |
person.familyName | OLIVEIRA | |
person.givenName | Pedro Manuel | |
person.givenName | Joao Heitor | |
person.givenName | Miguel Mesquita | |
person.givenName | Miguel | |
person.givenName | LUIS | |
person.identifier.orcid | 0000-0001-8285-1084 | |
person.identifier.orcid | 0000-0001-6487-7950 | |
person.identifier.orcid | 0000-0002-3080-6035 | |
person.identifier.orcid | 0000-0002-2198-7444 | |
person.identifier.orcid | 0000-0001-7532-5991 | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | aefa59ff-77f9-42ff-ac9b-88373f5c2ac8 | |
relation.isAuthorOfPublication | b1e9a3af-258b-4e7c-9ea6-bb2f67e31bfd | |
relation.isAuthorOfPublication | aa6920e7-d5c0-4d23-bd10-42317041c3e8 | |
relation.isAuthorOfPublication | d80c68f2-4ad1-4abb-8cd7-3b8572857cc7 | |
relation.isAuthorOfPublication | 68e21a43-a73d-4b4e-9255-09d9b601b55e | |
relation.isAuthorOfPublication.latestForDiscovery | aa6920e7-d5c0-4d23-bd10-42317041c3e8 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Baptista-2020-Asymmetric-thickness-intracorneal-r.pdf
- Size:
- 590.03 KB
- Format:
- Adobe Portable Document Format