Repository logo
 
Loading...
Profile Picture

Search Results

Now showing 1 - 8 of 8
  • Intense Pulsed Plus Low-Level Light Therapy in Meibomian Gland Dysfunction
    Publication . Marta, Ana; Baptista, Pedro Manuel; Marques, Joao Heitor; Almeida, Daniel; José, Diana; Sousa, Paulo; Barbosa, Irene
    Purpose: To analyse the clinical outcome in patients with meibomian gland dysfunction (MGD) who underwent intense pulsed light (IPL) plus low-level light therapy (LLL). Materials and methods: The prospective non-comparative study included identified by MGD patients with altered interferometry and lower loss area of the meibomian glands (LAMG), who underwent IPL plus LLL, between July 2020 and August 2020. A multimodal assessment was performed before, 2-3 weeks, and 6 months after treatment. The main outcome was lipid layer thickness (LLT) and the secondary outcomes were the ocular surface disease index (OSDI) score, presence of corneal fluorescein staining (CFS), blink rate (BR), Schirmer test (ST), tear meniscus height (TMH), tear osmolarity (OSM), non-invasive break-up time (NIBUT) and LAMG. Results: This study included 62 eyes of 31 patients, 61.3% female, with a mean age of 66.94±9.08 years at the time of IPL plus LLL treatment. LLT (<0.001) grades improved 6 months after treatment. The mean OSDI score improved (p<0.001) from 45.02±21.17 (severe symptoms) to 22.35±17.68 (moderate symptoms) at 2-3 weeks and 8.24±17.9.91 (normal) at 6 months after treatment. CFS was identified in 51.6% (32/62) before and in 45.2% (28/62) 6 months (p=0.293) after treatment. ST (p=0.014) grades improved; OSM grades mild worsened (p<0.001); TMH, NIBUT and LAMG grades did not modify 6 months after treatment. No patient suffered any adverse effects. Conclusion: IPL combined with LLL was effective and safe, improving the lipid layer thickness in MGD and decreasing the level of symptoms.
  • Long-Term Visual Function Effects of Pan-Retinal Photocoagulation in Diabetic Retinopathy and Its Impact in Real Life
    Publication . Baptista, Pedro Manuel; Marta, Ana; Marques, Joao Heitor; José, Diana; Almeida, Daniel; Ribeiro, António; Barbosa, Irene
    Purpose: To address the long-term visual function after bilateral pan-retinal photocoagulation (PRP) and its impact in real life, namely on visual field (VF) legal criteria to drive. To determine potential predictors related to clinical factors and treatment strategies. Patients and methods: Observational cross-sectional study. Eyes from diabetic patients diagnosed with diabetic retinopathy who underwent bilateral PRP, with or without macular treatments and with visual acuity legal criteria for non-professional driving were randomly assigned. Main outcomes were: demographic and clinical data including best corrected visual acuity; binocular visual field (EBST-Esterman Binocular Suprathreshold Test, Humphrey analyzer3®); contrast sensitivity (CS-Metrovision-MonPack3®); light scattering in the retina (HD Analyzer, Visiometrics®). Results: Seventy-one diabetic patients included (44 men and 27 women), with a mean age of 62.2±11.8 years. PRP was performed, on average, 9.7±6.9 years before the study. The average EBST Score was 85.8±17.0 and the average CS (2-5cpd) was 19.5±2.9 dB in photopic and 14.2±4.1 dB in mesopic conditions. Through a multivariate regression model, after adjusting to the clinical and demographic factors as possible confounders, we found that treatment factors associated with worse results were the use of Argon laser for the EBST Score, the very confluent PRP for the number of non-viewed points in the central 30°x20° of the EBST and the presence of macular treatments for the CS tests. According to Portuguese law, 79% (n=56) of patients had minimal EBST amplitudes for non-professional driving. Conclusion: The functional results achieved in our sample are compatible with an active life, allowing most of the patients included to overcome the requirements of Portuguese legislation for driving light vehicles, namely at the level of the binocular visual field. These results highlight the role of PRP in the treatment of diabetic retinopathy in an era with evolving less aggressive laser options.
  • Keratoconus and Visual Performance with Different Contact Lenses
    Publication . Marta, Ana; Marques, Joao Heitor; Almeida, Daniel; José, Diana; Barbosa, Irene
    Purpose: To analyze the visual performance in contact lens wearers with keratoconus. Methods: A retrospective study including contact lens (CL) wearers was performed. The current best-corrected visual acuity with contact lens (BCVA-CL) and with spectacles (BCVA-S) correction, contrast sensitivity (CS) (by Metrovision-MonPack3®), analysis of light scattering in the retina and vision break-up time (HD Analyzer®), and corneal tomography (Oculus Pentacam® HR) were evaluated. Results: This study included 96 eyes of 59 patients with Keratoconus. Rigid gas permeable contact lenses (RGPCL), hybrid contact lenses (HCL), and silicone hydrogel/hydrogel contact lenses (HGCL) were fitted in 67, 17, and 12 eyes, respectively. Dynamic objective scatter index (OSI) (p = 0.024), minimum OSI (p = 0.037) and maximum OSI (p = 0.040) were significantly better with RGPCL and worse with HGCL. Mean CS in photopic conditions was significantly worse with HGCL and better with HCL (p = 0.006), without differences in mesopic conditions (p = 0.121). RGPCL wearers showed a higher mean K (p = 0.020), and a lower corneal thickness at the thinnest point (p=0.011). Conclusion: Visual quality varied significantly with different types of CL. Although RGPCL was fitted in patients with worse Pentacam tomographic parameters, RGPCL was associated with a better dynamic visual quality.
  • Optical Coherence Tomography Findings (SD-OCT and OCTA) in Early-Stage Type 3 Neovascularization
    Publication . Silva, Nisa; Marta, Ana; Baptista, Pedro; Furtado, Maria João; Lume, Miguel
    A 76-year-old male presented with a small hyperreflective density in the outer nuclear layer with subtle retinal pigment epithelium (RPE) elevation and few intraretinal cysts on spectral-domain optical coherence tomography (SD-OCT). Optical coherence tomography angiography (OCTA) confirmed the presence of a tuft-shaped intraretinal neovascular lesion. SD-OCT performed 2 months before showed a smaller RPE elevation at the same location without intraretinal fluid. A 79-year-old male presented with a small hyperreflective density in the outer retina surrounded by scant intraretinal fluid on SD-OCT and a bright vessel on OCTA, suggesting early-stage type 3 neovascularization. SD-OCT performed 2 months before showed a smaller hyperreflectivity at the same location, without intraretinal fluid. An 84-year-old female presented with hyperreflective foci in the outer retina overlying a serous pigment epithelium detachment (PED) with focal RPE disruption on SD-OCT. SD-OCT performed 2 months before showed the same hyperreflective lesion associated with a shallower PED. No neovascular lesions were found on OCTA after six injections of bevacizumab. To conclude, careful evaluation of SD-OCT allows for early detection of type 3 neovascularization at a pre-exudative stage. OCTA may be useful in confirming the presence of intraretinal neovascular lesion and monitoring response to anti-vascular endothelial growth factor agents.
  • Exophiala Keratitis following Descemet Stripping Automated Endothelial Keratoplasty
    Publication . Marta, Ana; Costa, Paula; Lopes, Virgínia; Neves, Miguel Mesquita; Gomes, Miguel; OLIVEIRA, LUIS
    Purpose: To report a case with Exophiala spp. keratitis in a Portuguese patient. Methods: A case report with deep corneal brown-pigmented infiltrates that developed 2 months after a Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) for pseudophakic bullous keratopathy. Results: Diagnosis was established by positive direct examination and cultures from the surgically obtained corneal button. Slit-lamp images and anterior segment optical coherence tomography (AS-OCT) scans were obtained. Conclusion: This is the first described case of fungal keratitis caused by Exophiala spp. in Portugal and, to our knowledge, the first case following DSAEK in the literature.
  • A temporary corneal ectasia following airbag trauma
    Publication . Marta, Ana; Abreu, Ana Carolina; Monteiro, Sílvia; Pinto, Maria
    Purpose: To report a case of a temporary corneal ectasia induced by airbag trauma. Observations: A patient who suffered a road traffic accident with deployment of the frontal airbag and presented a corneal ectasia in both eyes after 3 months, without changes in visual acuity. After 9 months, he presented a significantly improvement, achieving his basal parameters in pentacam. Conclusions and importance: This is a rare case of corneal ectasia induced by airbag trauma that spontaneously reverted and it can emphasize the viscoelastic properties of the human cornea.
  • The Role of Corneal Biomechanics in the Assessment of Ectasia Susceptibility Before Laser Vision Correction
    Publication . Baptista, Pedro Manuel; Marta, Ana; Marques, Joao Heitor; Abreu, Ana Carolina; Monteiro, Sílvia; Menéres, Pedro; Pinto, Maria do Céu
    Purpose: To describe the tomographic and corneal biomechanical status of a sample of eyes excluded from LVC and to present the differences in biomechanical behavior in relation to cutoffs of clinical- and tomography-based screening methods used in clinical practice. Patients and methods: Observational cross-sectional study including 61 eyes from 32 consecutive patients who were excluded from LVC in our department. Clinical and demographic data were collected from the patients' clinical records. Tomographic data was assessed with a Scheimpflug camera (Pentacam, OCULUS®). Ablation depth (µm) and residual stromal bed (µm) were calculated by the WaveLight® EX500 laser system software (Alcon, EUA). The corneal biomechanical assessment was made through ultra-high speed Scheimpflug imaging during noncontact tonometry (Corvis ST, OCULUS®). Several ectasia risk scores were analyzed. Results: Mean age was 31.0±6 years old and mean manifest spherical equivalent was -2.01 ± 2.3D. Belin-Ambrósio deviation index was the tomographic parameter with higher proportion of eyes within the ectasia high risk interval. In the biomechanical assessment, more than 95% of eyes met the criteria for ectasia susceptibility in four of the first generation and in two of the second generation parameters. In a cutoff based comparative analysis, eyes with Kmax ≥45.5 D, eyes with VCOMA <0 and eyes with ARTmax ≤350 presented significantly softer corneal biomechanical behavior. Conclusion: The majority of eyes excluded from LVC in the present study met the criteria for ectasia susceptibility in several biomechanical parameters, validating the clinical and tomographic based screening prior to LVC in our center. Differences found in the biomechanical assessment regarding cutoffs used in clinical practice highlight its differential role in characterizing risk profile of these patients. Tomography should not be overlooked and the integration of all data, including treatment-related parameters, can be the future of risk ectasia screening prior LVC.
  • Comparison of Light-Based Devices in the Treatment of Meibomian Gland Dysfunction
    Publication . Castro, Catarina; Marques, Joao Heitor; Marta, Ana; Baptista, Pedro Manuel; José, Diana; Sousa, Paulo; Menéres, Pedro; Barbosa, Irene
    Purpose: To compare different light-based devices, namely, intense pulsed light (IPL) and IPL with low-level light therapy (LLLT), in the treatment of meibomian gland dysfunction (MGD). Methods: This was a prospective, observational study that included patients with MGD. Group 1 included 58 eyes treated with IPL (eye-light®, Espansione Marketing S.p.A., Bologna, Italy), followed by LLLT (my-mask®, Espansione Marketing S.p.A., Bologna, Italy); Group 2 included 60 eyes treated with IPL (E>Eye®, E-Swin, Houdan, France); and Group 3 included 58 eyes treated with IPL (Thermaeye Plus®, OptiMed, Sydney, Australia). The presence of symptoms (Ocular Surface Disease Index (OSDI)) and ocular surface changes were evaluated at baseline, three weeks, and six months after treatment. Results: At week three, there was an improvement in the OSDI in all groups (p<0.001), without differences among them (p=0.339). The lipid layer thickness (LLT) increased in Groups 1 and 2 (p<0.001), with a similar variation (p=0.144). Patients with superior OSDI and lower LLT at baseline had the greatest improvement in the respective parameters (p<0.001). The basal tear flow increased in Group 1 (p=0.012). Corneal staining (CS) significantly decreased in Groups 2 (p<0.001) and 3 (p<0.001). At six months, compared to three weeks, there was further improvement in the OSDI (p<0.001) and the LLT (p=0.007), in Group 1, and an increase in the presence of CS in Group 3 (p=0.011). Conclusion: IPL treatment led to a sustained decrease in patients' symptoms, even after six months. Different IPL devices seem to have different beneficial effects. Adding LLLT to IPL appears to have an additional long-term beneficial effect as well as positive effects on the lacrimal gland.