Browsing by Author "Pedroto, I."
Now showing 1 - 10 of 25
Results Per Page
Sort Options
- 3D echoendoscopy and miniprobes for rectal cancer stagingPublication . Castro-Poças, F.; Dinis-Ribeiro, M.; Rocha, A.; Araújo, T.; Pedroto, I.Background: rectal cancer staging using rigid probes or echoendoscopes has some limitations. The aim of the study was to compare rectal cancer preoperative staging using conventional endoluminal ultrasonography with three-dimensional endoscopic ultrasonography and miniprobes. Materials and methods: sixty patients were included and evaluated with: a) a conventional echoendoscope (7.5 and 12 MHz); b) miniprobes (12 MHz); and c) the Easy 3D Freescan software for three-dimensional endoscopic ultrasonography. The reference or gold standard was conventional endoluminal ultrasonography in all cases and pathological assessment for those without preoperative therapy. The differences in T and N staging accuracy in both longitudinal and circumferential extension were evaluated. Results: with regard to T staging, conventional endoluminal ultrasonography had an accuracy of 85% (compared to pathological analysis), and the agreement between miniprobes vs conventional endoluminal ultrasonography (kappa = 0.81) and three-dimensional endoscopic ultrasonography vs conventional endoluminal ultrasonography (k = 0.87) was significant. In addition, miniprobes had an accuracy of 82% and three-dimensional endoscopic ultrasonography had a higher accuracy (96%). With regard to N staging, conventional endoluminal ultrasonography had an accuracy of 91% with a sensitivity of 78%. However, the agreement between miniprobes and conventional endoluminal ultrasonography and three-dimensional endoscopic ultrasonography and conventional endoluminal ultrasonography (k = 0.70) was lower. Interestingly, miniprobes had a lower accuracy of 81% whereas three-dimensional endoscopic ultrasonography had an accuracy of 100% without any false negative. No false positives were observed in any of the techniques. Accuracy for T and N staging was not influenced by longitudinal or circumferential extensions of the tumor in all types of endoscopic ultrasonography analyzed. Conclusions: miniprobes and especially three-dimensional endoscopic ultrasonography may be relevant during rectal cancer staging.
- Anorectal melanoma: an uncommon and aggressive diseasePublication . Magalhães, M.; Salgado, M.; Pedroto, I.
- Antiplatelet agents and/or anticoagulants are not associated with worse outcome following nonvariceal upper gastrointestinal bleedingPublication . Teles-Sampaio, E.; Maia, L.; Salgueiro, P.; Marcos-Pinto, R.; Dinis-Ribeiro, M.; Pedroto, I.BACKGROUND: Nonvariceal upper gastrointestinal bleeding emerges as a major complication of using antiplatelet agents and/or anticoagulants and represents a clinical challenge in patients undergoing these therapies. AIM: To characterize patients with nonvariceal upper gastrointestinal bleeding related to antithrombotics and their management, and to determine clinical predictors of adverse outcomes. METHODS: Retrospective cohort of adults who underwent upper gastrointestinal endoscopy after nonvariceal upper gastrointestinal bleeding from 2010 to 2012. The outcomes were compared between patients exposed and not exposed to antithrombotics. RESULTS: Five hundred and forty-eight patients with nonvariceal upper gastrointestinal bleeding (67% men; mean age 66.5 ± 16.4 years) were included, of which 43% received antithrombotics. Most patients had comorbidities. Peptic ulcer was the main diagnosis and endoscopic therapy was performed in 46% of cases. The 30-day mortality rate was 7.7% (n = 42), and 36% were bleeding-related. The recurrence rate was 9% and 14% of patients with initial endoscopic treatment needed endoscopic retreatment. There were no significant differences between the exposed and non-exposed groups in most outcomes. Co-morbidities, hemodynamic instability, high Rockall score, low hemoglobin (7.76 ± 2.72 g/dL) and higher international normalized ratio (1.63 ± 1.13) were associated significantly with mortality in a univariate analysis. CONCLUSIONS: Adverse outcomes were not associated with antithrombotic use. The management of nonvariceal upper gastrointestinal bleeding constitutes a challenge to clinical performance optimization and clinical cooperation.
- Colon carcinoma staging by endoscopic ultrasonography miniprobesPublication . Castro-Pocas, F.; Dinis-Ribeiro, M.; Rocha, A.; Santos, M.; Araújo, T.; Pedroto, I.BACKGROUND AND OBJECTIVES: Due to the increasing use of endoscopic techniques for colon cancer resection, pretreatment locoregional staging may gain critical interest. The use of endoscopic ultrasonography (EUS) miniprobes in this context has been seldom reported. Our aim was to determine the accuracy of EUS miniprobes for colon cancer staging. MATERIALS AND METHODS: Forty patients with colon cancer (2 in the cecum, 9 in the ascending colon, 5 in the transverse colon, 5 in the descending colon, and 19 in the sigmoid colon) were submitted to staging using 12 MHz EUS miniprobes. EUS and the anatomopathological results were compared with regard to the T and N stages. It was assessed if the location, longitudinal extension, or circumferential extension of the tumor had any influence on the accuracy in EUS staging. RESULTS: Tumor staging was feasible in 39 (98%) patients except in one case with a stenosing tumor (out of 6). Globally, T stage was accurately determined in 88% of the cases. In the assessment of the presence or absence of lymph node metastasis, miniprobes presented an accuracy of 82% with a sensitivity of 67%. These results were neither affected by the location nor by the longitudinal or circumferential extension of the tumor. CONCLUSIONS: EUS miniprobes may play an important role in assessing T and N stages in colon cancer and may represent an incentive to the research of new therapeutic areas for this disease.
- Crohn's disease and systemic lupus erythematosus: A rare and challenging associationPublication . João-Magalhães, M.; Lago, P.; Pedroto, I.
- Endoscopic Removal of Two Esophageal Over-The-Scope Clips with Cold Saline Solution TechniquePublication . Rocha, M.; Küttner-Magalhães, R.; Maia, L.; Moreira, T.; Barrias, S.; Nogueira, C.; Pedroto, I.
- Endoscopic ultrasound of pneumatosis cystoides intestinalisPublication . Castro-Poças, F.; Araújo, T.; Pedroto, I.
- Evolução do Processo de Avaliação e Controlo de RiscosPublication . Pereira, L.F.; Pedroto, I.; Freitas, M.; Oliveira, M.M.; Pacheco, H.
- Gastric peroral endoscopic myotomy for transthyretin amyloidosis gastroparesisPublication . Guedes, T.; Küttner-Magalhães, Ricardo; Maia, L.; Sousa, J.; Garrido, M.; Pedroto, I.
- Health-related quality of life and utilities in gastric premalignant conditions and malignant lesions: a multicentre study in a high prevalence countryPublication . Areia, M.; Alves, S.; Brito, D.; Cadime, A.; Carvalho, R.; Saraiva, S.; Ferreira, S.; Moleiro, J.; Pereira, A.; Carrasquinho, J.; Lopes, L.; Ramada, J.; Marcos-Pinto, R.; Pedroto, I.; Contente, L.; Eliseu, L.; Vieira, A.; Sampaio, M.; Sousa, H.; Almeida, N.; Gregório, C.; Portela, F.; Sofia, C.; Braga, V.; Baginha, E.; Bana e Costa, T.; Chagas, C.; Mendes, L.; Magalhães-Costa, P.; Matos, L.; Gonçalves, F.; Dinis-Ribeiro, M.BACKGROUND AND AIMS: A recent review of economic studies relating to gastric cancer revealed that authors use different tests to estimate utilities in patients with and without gastric cancer. Our aim was to determine the utilities of gastric premalignant conditions and adenocarcinoma with a single standardized health measure instrument. METHODS: Cross-sectional nationwide study of patients undergoing upper endoscopy (n=1,434) using the EQ-5D-5L quality of life (QoL) questionnaire. RESULTS: According to EQ-5D-5L, utilities in individuals without gastric lesions were 0.78 (95% confidence interval: 0.76-0.80), with gastric premalignant conditions 0.79 (0.77-0.81), previously treated for gastric cancer 0.77 (0.73-0.81) and with present cancer 0.68 (0.55-0.81). Self-reported QoL according to the visual analogue scale (VAS) for the same groups were 0.67 (0.66-0.69), 0.67 (0.66-0.69), 0.62 (0.59-0.65) and 0.62 (0.54-0.70) respectively. Utilities were consistently lower in women versus men (no lesions 0.71 vs. 0.78; premalignant conditions 0.70 vs. 0.82; treated for cancer 0.72 vs. 0.78 and present cancer 0.66 vs. 0.70). CONCLUSION: The health-related QoL utilities of patients with premalignant conditions are similar to those without gastric diseases whereas patients with present cancer show decreased utilities. Moreover, women had consistently lower utilities than men. These results confirm that the use of a single standardized instrument such as the EQ-5D-5L for all stages of the gastric carcinogenesis cascade is feasible and that it captures differences between conditions and gender dissimilarities, being relevant information for authors pretending to conduct further cost-utility analysis.
- «
- 1 (current)
- 2
- 3
- »